LEWA RECIPROCATING METERING PUMP
 
LEWA HYGIENIC/SANITARY Pump Series

  LEWA API675 Pump Series

The innovative and universal metering pumps with Diaphragm Protection System DPS series in proven modular design can be applied in various conditions to meet the needs. With the consistently further developed LEWA ECOFLOW series an optimal, customized design for almost every application can be configured from the abundance of standardized assemblies. Therefore it is possible to offer the already legendary LEWA quality at a marketable price. For special technical requirements which cannot be covered by our modular system we are in the position to offer special solutions based on over 50 years of experience. LEWA ecoflow is the most progressive diaphragm metering pump worldwide and offers maximum safety for production and environment:

  • Meet the requirements of API 675 according to the American Petroleum Association and the standards as VDMA 24284, 24286-10, 3A, FDA guidelines.
  • Satisfy the grading requirements of food and hygiene.
  • Lowest life cycle costs. Lowest maintenance costs.
  • Extremely long service life of the sandwich diaphragm (18 months warrantee).
  • Simple diaphragm replacement.
  • Use of LEWA CMS possible as an option.
  • Highest reliability and availability.
  • Absolute safe start-up of the pump.
  • Patented diaphragm protection system (DPS) Diaphragm monitoring system –safe control of the diaphragm movement.
  • Highest reliability even in case of mal-operation or extreme operating conditions such as high suction pressure, closed discharge- or suction line.

  1. LEWA ECOFLOW PUMP SERIES:

    • Meet the requirements of API 675 according to the American Petroleum Association and the standards as VDMA 24284, 24286-10, 3A, FDA guidelines. High reliability and adaptability.
    • Satisfy the grading requirements of food and hygiene.
    • On the material for parts in contact with the fluid, there are two options to choose from, either stainless steel or PVC. The metering quantity can either be adjusted manually, automatic stroke controlled, and frequency speed controlled on the motor drive.
    • In combination with the patented DPS (Diaphragm Protection System), the long service life of diaphgram can be ensured.
    • Easy replacement of sandwich diaphragm. The patented 4-layer PTFE sandwich-diaphragm provides increased safety and high-precision metering. LEWA ecodos safety diaphragms have a service life of more than 16,000 operating hours, i.e. two years of continuous operation. Therefore, the warranty period for diaphragms is two years.
    • Ecoflow can be added with LEWA CMS Monitor System for great performance。
    • Depending on the process requirements, there are multiple pump head connection options to choose from.
  2. Choose either diaphragm or plunger pump:

    Diaphgram Type
    (Click the above image to see the under hood diagram〉
    Plunger Type
    (Click the above image to see the under hood diagram〉

    Flow rates up to 10 m³/hr per pump head
    Discharge pressure up to 1,200 bar

    〈Click on the above image to enlarge〉

    Ecoflow Catalog

     

  3. LEWA ECOSMART SERIES:

    • Meet the requirements of API 675 according to the American Petroleum Association. High reliability and adaptability.

    • Compact design. Flow rates up to 271 l/hr per pump head. Discharge pressure up to 80 bar.

    • On the material for parts in contact with the fluid, there are two options to choose from, either stainless steel or PVC.

    • The metering quantity can either be adjusted manually, automatic stroke controlled, and frequency speed controlled on the motor drive.

    • Ecosmart Catalog

    • Ecosmart PVC Catalog

  4. Sandwich Diaphragm Design

    〈Click on the above image to enlarge〉


  LEWA ECODOS SERIES

  • LEWA ecodos diaphragm pumps are characterised by their extremely high metering accuracy. Flow rate fluctuations are less than ± 1% in a stroke length adjustment range of 5:1.
  • The patented 4-layer PTFE sandwich-diaphragm provides increased safety and high-precision metering. LEWA ecodos safety diaphragms have a service life of more than 16,000 operating hours, i.e. two years of continuous operation. Therefore,the warranty period for diaphragms is two years.
  • The flow rates can be adjusted variably: manual adjustment, automatic stroke adjustment, and frequency inverter.
  • Flow rates up to 1.5 m³/hr per pump head. Discharge pressure up to 20 bar.

 

4-layer safety PTFE diaphragm design, from left to right as follows:

  • 1st layer: working diaphragm
  • 2nd layer: working diaphragm
  • 3rd layer: monitoring diaphragm
  • 4th layer: pressure-resistant safety diaphragm

Ecodos Catalog

 

〈上圖連結放大詳圖〉

 

  LEWA MICROFLOW LAB METERING SERIES

Microflow lab metering series pumps are mainly used in the laboratory and for process development in pilot plants. The pumps are designed using the metal diaphragm technology. There are MAH series, MBH series, MLM series, M series and FC series. Microflow lab metering series pumps can be connected to MSG desktop control panel and OLK control panel.

MLM 15(ex-proof) FC 1 plunger pump head M series: M3,M5,M8
MAH-5 / MAH-3(ex-proof) MBH series Control MSG
  1. MLM Series: maximun metering flow: 57.5 l/hr, maximun operating pressure: 560 bar
  2. FC Series: maximun metering flow: 67.86 l/hr, maximun operating pressure: 400 bar
  3. M Series: maximun metering flow: 1.8 l/hr, maximun operating pressure: 50 bar
  4. MAH Series: maximun metering flow: 1.8 l/hr, maximun operating pressure: 50 bar
  5. MBH Series: maximun metering flow: 2400 l/hr, maximun operating pressure: 50 bar
Microflow-metering pumps series MAH, MLM, MBH
Microflow-metering pumps series FC

 

  Hygienic/Sanitary Pumps

LEWA hygienic and sanitary pumps meet the strict production requirements for pharmaceutical, biotechnical, personal care and food industries. They can also be integrated with other components to become a packaging system.

LEWA Ecoflow Hygienic Pumps with SUS316L pump head:
  • Diaphragm Protection System (DPS) integrated. For medium and high operating pressure.
  • Wetted parts Ra < 0.5μm, electro-polished.
  • Designed to be CIP(clean in place).
  • Designed to be SIP(steam in place) up to 150°C (300°F).
  • Large modular system, adaptable to any application.

 

LEWA Ecodos Hygienic Pump with SUS316L pump head:
  • Wetted parts Ra < 0.5μm, electro-polished.
  • Designed to be CIP.
  • Designed to be SIP up to 150°C (300°F).

 

LEWA Ecodos Hygienic Pump with PP pump head:
  • Reliable and efficient series for low operating pressures.
  • Excellent chemical resistance. Polypropylene pump heads with excellent surface quality.
  • Up to 60°C (140°F), designed to be CIP (clean in place).
  • EPDM or FFPM seals.
  • All wetted materials tested and meeting for FDA, 3A, QHD, EHEDG requirements.

 

LEWA Ecodos Sanitary Pumps with 316Ti pump head:
  • Wetted parts Ra < 0.8μm, mechnical-polished. Corrosion proof and easy surface cleaning.
  • All wetted materials tested for FDA conformity.
  • Designed to be CIP (clean in place).
  • For easy integration into existing or new process lines, tri-clamp or other design sanitary fittings are available to meet user requirements.
 
|Best view with IE 5.0, recommended resolution 800x600.|